Mapping cancer: blue denotes healthy tissue red pre-malignant and yellow malignant. This megapixel sensor has a pixel size of 8µm and operates at up to 12.4 frames per second." This enables single photon sensitivity from a TE-cooled, USB 2.0 camera platform. Orla Hanrahan, of Andor, commented, "The Luca-R EMCCD camera is designed around a monochrome, megapixel frame-transfer EMCCD sensor. What’s more, imaging the entire region may also help the surgeons to identify the margins of the lesion that cannot be easily visualized by the naked eye during surgical interventions." "It also delineates the boundaries of neoplastic changes and locates sites with the most malignant potential for biopsy, thereby avoiding unnecessary repeated biopsies and delay in diagnosis. Our imaging method has the great advantage of non-invasively scanning entire lesions and their surrounding areas and automatically categorizing these oral lesions into normal, pre-malignant, and malignant tissue in real-time. This allows rapid visual differentiation of oral lesions and identification of regions with pre-malignant characteristics.ĭr Subhash commented, "Since mortality from oral cancer is particularly high, early detection, diagnosis and treatment is vital in increasing the survival rate of those with the disease.
ANDOR SOLIS AUTOMATED DATACOLLECTION SOFTWARE
Water assisted cooling will always be better than air-cooling.Dr Narayanan Subhash.Andor’s SOLIS software then computes a ratio image of the area under investigation, based on the images captured at the two wavelengths, and generates a pseudo colour map (PCM), in which blue designates healthy tissue, red denotes dysplastic/pre-malignant tissue, and yellow identifies malignant tissue.TE cooling to a minimum temperature of -100☌ with water assisted cooling and -80☌ with air cooling for optimal Signal to Noise (S/N) performance.You never need to repump an Andor detector
![andor solis automated datacollection andor solis automated datacollection](https://www.mdpi.com/cancers/cancers-13-04767/article_deploy/html/images/cancers-13-04767-g003-550.jpg)
ANDOR SOLIS AUTOMATED DATACOLLECTION FREE
Assembled in a state-of-the- art Class 10,000 cleanroom facility Andor's proprietary UltraVac™ process (all metal, glass and ceramic) is based on military technology and has been designed for more than 25 years of maintenance free operation. Exclusive maintenance free design from the vacuum experts.Dual output: the option of a conventional "high responsivity" output for ultra low light applications or an EM output for single photon sensitivity.Minimum operating temperature of -100☌ provides negligible dark current and optimizes EMCCD gain.Multi-MHz readout with USB 2.0 connectivity.
ANDOR SOLIS AUTOMATED DATACOLLECTION FULL
![andor solis automated datacollection andor solis automated datacollection](https://embed-ssl.wistia.com/deliveries/a7d48f1e84ae91500634451b52e57556e31eeb3a.jpg)
High performance, and extreme versatility make this the ideal CCD detector to use with Andor's line of Shamrock imaging spectrographs to form a very powerful spectroscopy measurement system for use in even the most demanding applications. The Newton CCD detector also provides dual output amplifiers for user selection of high sensitivity or high capacity operating modes.
![andor solis automated datacollection andor solis automated datacollection](https://img.medicalexpo.com/images_me/photo-m2/84543-16504940.jpg)
ANDOR SOLIS AUTOMATED DATACOLLECTION SERIES
The Newton series of conventional CCD detectors employ industry leading low noise CCD sensors such as the 2048 x 512 and the 1024 x 256 pixel formats optimized for spectroscopy along with the standard features of ultra low noise electronics, deep cooling, high QE, multi-MHz readout, and USB 2.0 connectivity. Dual output amplifiers also allow the detector system to operate in both the electron-multiplication mode and the conventional low noise readout modes, making the detector even more versatile for a wider variety of applications. The combination of the Newton's low noise electronics, high QE, fast readout, and the on-chip amplication (electron multiplication) makes this detector unbeatable for the most demanding ultra-low light level spectroscopy applications, including single photon light level spectra. The Newton EM employs Andor's pioneering electron multiplying CCD technology in an exclusive sensor format optimized for ultra-low light, level spectroscopy applications. All Newton detector systems employ low noise electronics, cooling to -100☌, up to 95% peak Quantum Efficiency (QE), multi-MHz readout, USB 2.0 connectivity and versatile readout modes. Both the Andor Newton EM EMCCD and Newton conventional CCD detector systems have been optimized for high performance spectroscopic applications.